2.5" Models    
   3.0" Models    
   4.0" Models    
    
    TFC    
    OMNI    
    CTA    
Pressure Vessels    
    
TFC (light   duty)    
    TFC    
    CTA    
2.5" Pressure Vessels    
4" Pressure Vessels    
  
    T3213-500    
  N112-100XC    
  T3420-600    
ELF T3014-300    
ELF T3014-400    
ELF N3014-500    
  

    

Additional 
Data Sheets
  

 

 

 

 

OSMOTIK Membranes

Seawater RO Elements for Marine Systems

2.5" Diameter Models

 

Features

  • Improved OSMOTIK® seawater reverse osmosis elements offer the highest productivity while maintaining excellent salt rejection.
  • OSMOTIK® SW30 membranes elements have the highest flow rates available to meet the water demands of both sea-based and land-based desalinators.
  • OSMOTIK® SW30 elements may also be operated at lower pressure to reduce pump size, cost and operating expenses.
  • Improved OSMOTIK® seawater membrane combined with automated, precision element fabrication result in the most consistent product performance available.

 

Product Specifications

 

Product Applied Pressure
psig (bar)
Permeate Flow
Rate gpd (m³/d)
Stabilized Salt
Rejection (%)
SW30-2514-150 800 (55) 150 (0.6) 99.5
SW30-2521-300 800 (55) 300 (1.1) 99.5
SW30-2540-700 800 (55) 700 (2.6) 99.5
  1. Permeate flow and salt rejection based on the following test conditions: 32,000 ppm NaCI, pressure specified above, 77°F (25°C) and the following recovery rates: SW30-2514-2%, SW30-2521-5% & SW30-2540-8%.
  2. Permeate flows for individual elements may vary +/-20%.
  3. For the purpose of improvement, specifications may be updated periodically.

Figure 1

 

Product Maximum Feed
Flow Rage gpm
(m3/h)
Dimensions – Inches (mm)
A B C D
SW30-2514-150 6 (1.4) 14.0 (356) 1.19 (30.2) 0.75 (19) 2.4 (61)
SW30-2521-300 6 (1.4) 21.0 (353) 1.19 (30.2) 0.75 (19) 2.4 (61)
SW30-2540-700 6 (1.4) 40.0 (1,016) 1.19 (30.2) 0.75 (19) 2.4 (61)
  1. SW30-2514, SW30-2521 & SW30-2540 elements fit nominal 2.5 inch I.D. pressure vessel.
  2. Pressure rating must be verified from the vessel manufacturer

 

Operating Limits

 

Membrane Type High Rejection Polyamide Thin-Film Composite
Maximum Operating Temperature 115°F (46°C)
Maximum Operating Pressure  1,000 psi (69 bar)
Maximum Pressure Drop 14.4 psig (1.0 bar)
pH Range, Continuous Operation 3-11
pH Range, Short-Term Cleansing 1-13
Maximum feed Silt Density Index  SDI 5
Free Chlorine Tolerance <0 ppm
  1. Maximum temperature for continuous operation above pH 10 is 95°F (35°C)
  2. Refer to Cleaning Guidelines
  3. Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure.  Since oxidation damage is not covered under warranty, Osmotik recommends removing residual free chlorine by pretreatment prior to membrane exposure.

 

Important Information

Proper start-up of reverse osmosis water treatment systems is essential to prepare the membranes for operating service and to prevent membrane damage due to overfeeding or hydraulic shock.  Following the proper start-up sequence also helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved.

Before initiating system start-up procedures, membrane pretreatment, loading of the membrane elements, instrument calibration and other system checks should be completed.

Please follow instructions provided by reverse osmosis system manufacturer.

 

Operation Guidelines

Avoid any abrupt pressure or cross-flow variations on the spiral elements during start-up, shutdown, cleaning or other sequences to prevent possible membrane damage.  During start-up, a gradual change from a standstill to operating state is recommended as follows:

  • Feed pressure should be increased gradually over a 30-60 second time frame.
  • Cross-flow velocity at set operating point should be achieved gradually over 15-20 seconds.
  • Permeate obtained from first hour of operation should be discarded.

 

General Information

  • Keep elements moist at all times after initial wetting.
  • If operating limits and guidelines given in this bulletin are not strictly followed, the limited warranty will be null and void.
  • To prevent biological growth during prolonged system shutdowns, it is recommended that membrane elements be immersed in a preservative solution.
  • The customer is fully responsible for the effects of incompatible chemicals and lubricants on elements.
  • Maximum pressure drop across an entire pressure vessel (housing) is 50 psi (3.4 bar).
  • Avoid static permeate-side backpressure at all times.

Notice:  The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent on the complete system design and on the operation and maintenance of the system.

Notice: No freedom from any patent owned by Osmotik or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate for customer’s use and for ensuring that customer’s workplace and disposal practices are in compliance with applicable laws and other government enactments.  Osmotik assumes no obligation or liability for the information in this document. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.

 

 

Original Equipment Manufacturer, no retail sales
Please contact us to for additional  custom options such as private labeling, special colors, new styles and configurations.