Reverse Osmosis Information
Storage
TFC*Storage
Spirals manufactured from this membrane are 100% performance tested on Buena
Park filtered tap water at 60 psig (4.1 atm) applied pressure. Productivity is corrected
to 77º F (25º C). Nominal rejection is 97% to 98% (95% minimum) and nominal
productivity is rated value ± 15%. Refrigerated storage is best for maximum life,
but not a requirement. We do recommend leaving spirals in their original packaging
until needed.
- Spirals are sanitized with 1.5 weight percent sodium metabisulfite. Spirals are nitrogenflushed and vacuum bagged or encapsulated into a housing.
- Spirals must NOT be allowed to dry.
- Spirals must NOT be allowed to freeze.
Rinsing and preparation for use:
- Use only potable dechlorinated (0 ppm Total Chlorine) feed water.
- Rinse to drain a minimum of 3 hours.
- Nominal pH limits are 4.0 to 11
- Allowable feed water Temperature range is 34°F to 113°F (1°C - 45°C).
* Manufactured and licensed under U.S. Patent No. 4,277,344.
CTA Storage
Spirals manufactured from this membrane are 100% performance tested on Buena
Park filtered tap water at 60 psig (4.1 atm) applied pressure. Productivity is corrected
to 77º F (25º C). Nominal rejection is 94% to 95% (93% minimum) and nominal
productivity is rated value ± 15%. Refrigerated storage is best for maximum life,
but not a requirement. We do recommend leaving spirals in their original packaging
until needed.
- Spirals are sanitized with 1.5 weight percent sodium metabisulfite. Spirals are nitrogen
flushed and vacuum bagged or encapsulated into a housing.
- Spirals must NOT be allowed to dry.
- Spirals must NOT be allowed to freeze.
Rinsing and preparation for use:
- Use only potable dechlorinated (0 ppm) feed water.
- Rinse to drain a minimum of 3 hours.
- Nominal pH limits are 3.0 to 8.0.
- Allowable feed water Temperature range is 40°F to 110°F (4.4°C - 43°C).
Back to RO Information
|